COMPARISON
OF "SNEHANKIT POWER TEMPLE" WITH |
| S.No. | EXISTING | PROPOSED |
| 1. | Open to Atmosphere, outdoor type | Enclosed - Indoor Type |
| 2. | Point of operation is just below the system. Risk of Operator getting affected by sparks, etc. exists. | Point
of Operation is far away from the system. Risk of sparks falling on the operator is totally eliminated. |
| 3. | Operation is by simple links and levers. Contact settings get disturbed during operations. | Operation is by gear link solid shaft coupled with earth switch for outgoing cable earthing when G.O.D. is made off. |
| 4. | Access for maintenance is difficult due to height of system (11 mtr.) | Easy access for maintenance being indoor and at lesser height ( 3 mtr.) |
| 5. | Transportation, installation, operation and maintenance is difficult because of the height. | Transportation,
installation, operation and maintenance is very easy. |
| 6. | Difficult to identify and rectify faults during down pour. | No difficulty. |
| 7. | Separate
Meter Room of area 3 mtr x 3 mtr.is required. |
No
separate meter room is required as Metering system is part of the KIOSK. |
| 8. | Lightning
Arrestor is required since it is an out-door system. |
Lightning
Arrestor not required. Since it is an indoor system. |
| 9. | More No. of earthing pits are required. | Less No. of earthing pits are required. |
| 10. | Space requirement is more say 5 mtr X 5 mtr and separate meter room of size 3 mtr X 3 mtr. plus transformer space of 3 mtr X 3 mtr. | Space requirement is less, say 3 mtr X 3 mtr.and no separate space is required for meter room plus transformer space. |
| 11. | Requires periodic painting | Transportation
of total system is possible in one truck in one trip. |
| 12. | Point of supply is located at the front portion thereby affecting the aesthetic outlook of establishment. | No
painting is required as the material of construction is Galvanized. |
| 13. | Overhead conductors are provided. Due to this, possibility of snapping of conductor exists. | Due
to less height of the cabin (FRP/ Fibre Glass cabin) better outlook is ensured. |
| 14. | Reliability
of supply cannot be assured, since it is open system. |
Underground
cabling. And inside Kiosk, bus bars with Raychem insulation are provided. Due to nut bolting arrangement no possibility of snapping of bus bars exists. |
| 15. | Fencing, metal spreading required. | Ensures Reliability of supply. |
| 16. | Annual Painting and preventive maintenance required. | Not Required. |
| 17. | G.O.D.
and D.O. mechanical operations and contacts gets affected due to
atmosphere (rain and pollution) |
Annual
painting not required. Preventive maintenance very less. |
| 18. | Replacement of D.O. is very difficult job because of height. | Due
to enclosure, there is no such possibility. |
| 19. | MSEB Kiosk which is of metal body it is not advisable to go near kiosk with umbrella in rainy season. | D.O.'s
can be changed very easily, since height is very less. |
| 20. | With metal Kiosk following disadvantages are there. | It
is possible to go near the temple in rainy season with umbrella. |
| 21. | a) It is a electrical conducting material. | By
using FRP Following advantages are there. |
| b) Corrosion Problem | a) It is a insulating surface. | |
| c) Thermal Conductivity | b) Non Corrosion. | |
| For 4 pole structure arrangement standerdisation is not there. | c) Non thermal conductivity. | |
| 22. | Power
temple is a step towards standardisations. |
|
||||||||||||||||||